Error message 5734: Motion control synchronization error on Magnus 400


Product

 
  • Magnus™ 400
  • Magnus 400 Xpose

Component

 
  • LIF/LMCE board cable connections
  • LIF board
  • LIF/LMCE board cable
  • LMCE board

Error

  5734: A problem occurred in the Data Path because of motion control synchronization error.

Cause

 

Incorrect synchronization information regarding the drum and carriage movements was relayed between the LIF and LMCE boards.


Solution

 

After each adjustment or part replacement, check whether the problem is resolved. If not, proceed to the next step.

  1. Verify that the cable between the LIF and the LMCE boards is firmly connected.
  2. Run the LIF board diagnostic tests.
    • The test passes—proceed to step 3.
    • The test fails—replace the LIF board.
  3. To check the cable between the LIF and LMCE boards, send a simulation job:
    1. In Controller, in expert mode, select Hardware > Board > LIF2 Data Card.
    2. In the Exposure Mode section, select Simulation.
    3. In the list, select Drum NOT rotate, lasers NOT activated.
    1. Expose the job.
      • The test passes—proceed to step 4.
      • The test fails—replace the LIF/LMCE cable.
  4. Replace the LMCE board.

Technical contact(s)
 

Mario Amir

Submitted by
 

Shay Amsili

Date submitted
 

23 Mar 2005