Error message 5739: Laser driver overload on Magnus 400


Product

 
  • Magnus™ 400
  • Magnus 400 Xpose

Component

 
  • LDA (Laser Device Array) cables and cable connections
    • Cable between LDA driver and LDA head
    • Cable connection between LDA driver and LIF board.
  • LDA board

Error

 

5739: A problem occurred in Laser Device because current overload in laser driver


Cause

 

The scan mechanism on the LDA driver detects a current above ~1 A, which could cause damage to the LDA.


Solution

 

After each adjustment or part replacement, check whether the problem is resolved. If not, proceed to the next step.

  1. Verify that the cable connections between the LDA driver and the LDA head or LIF board are not loose.
  2. Verify that the cables between the LDA driver and the LDA head or LIF board are functioning, and replace any cable that is not functioning.
  3. Run diagnostics on the LDA board.
  4. If the LDA board does not pass diagnostic testing, replace the LDA board.

Technical contact(s)
 

Mario Amir

Submitted by
 

Shay Amsili

Date submitted
 

10 Aug 2005