Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Head banding in FM25 screens with Staccato on Magnus 400


Product

 
  • Magnus™ 400
  • Staccato®
  • Kodak® Thermal Gold™ plates

Symptoms

 

Head banding appears on Kodak Thermal Gold plates in FM25 screens with Staccato screening software. This occurs at a setting of 1200 rpm, 210 mW.


Cause

  Different types of plates require different focus motor settings.

Solution

 
  • Fuji plates: set the focus motor to the sharpest point achieved in the focus calibration test.
  • Kodak Thermal Gold: set the focus motor to 10 microns more than the sharpest point achieved in the focus calibration test.

Technical contact(s)
 

Mario Amir

Submitted by
 

Vince Beyer

Date submitted
 

06 Nov 2005


    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.