Edge detection does not work properly on 0.15 mm plates


Product

 
  • Kodak® Magnus™ 400 platesetter

Error

 
  • Plate Edge Detection Task failed.
  • Edge not accurate failure.

Symptoms

 
  • On startup, edge detection calibration is performed automatically. When using 0.15 mm plates or 0.3 mm plates, the first time a job is submitted with 0.15 mm plates, the following error messages appear:
    Plate Edge Detection Task failed. Edge not accurate failure.
  • When running the edge detection calibration test, the laser fails to locate the edge of the plate.

Cause

 

The platesetter cannot perform expose.


Solution

 
  1. Verify that the plate is securely attached to the drum.
  2. Run an edge detection calibration test without the punch.
  3. Replace the edge detection board.
  4. Replace the LMCE board.

Technical contact(s)
 

Alon Davidor

Submitted by
 

Alon Davidor

Date submitted
 

11 Jan 2007