Focus motor fails intermittently to locate home postiton


Product

 
  • Kodak® Magnus™ 400 platesetter
  • Kodak Lotem® 400 platesetter
  • Kodak Lotem 800 platesetter

Error

 
  • The task Focus Motor Go Pos failed.
  • Operation is not successful. Expose task failed.

Symptoms

 

When sending an expose job to a Lotem or Magnus platesetter, the focus motor fails intermittently to locate home position (HP) and calibration is not performed.


Cause

 
  • Faulty focus motor, Local3 board, or D-Box,
  • The values defined for the focus parameters are not correct.

Solution

 

Workaround: Before exposing the job, in the Controller software, manually move the focus motor to HP.
Note: If you cannot move the focus motor using the Controller software, replace the focus motor.

If the problem persists after replacing the focus motor:

  1. Run diagnostics.
  2. For Magnus 400 platesetters with D-box types A or B, verify that the key is 230 V.
  3. Replace the Local3 board.
  4. Replace the D-box.

See also

 

Problem with focus motor


Technical contact(s)
 

Alon Davidor