Expose fails on Magnus 400


Product

 
  • Kodak® Magnus™ 400 platesetter

Error

 
  • A problem occurred in the Data Path because of corrupted data.
  • A interruption occurred in Data Path.
  • The operation "Start expose" of Lif Data Card" failed.

Symptoms

 
  • An error appears at the beginning of the expose process.
  • Plates are not exposed.
  • Toward the end of the expose process an error appears.
  • The platesetter is ready to start imaging, but cannot start the expose process.

Cause

 
  • Images do not appear on the plate.
  • Expose is aborted.

Solution

 
  1. Verify that all cable connections between the LIF board and E-box are properly connected.
  2. Replace the LIF board.
  3. Replace the Local3 board.
  4. Replace the LDA driver board.

Technical contact(s)
 

Alon Davidor

Submitted by
 

Alon Davidor

Date submitted
 

11 Jan 2007