Home | Contact Us | Submit Troubleshooting Info | Search | Help
Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS
|
|
|||
Product |
|
||
|
|
|||
Cause |
When using Kodak P0048 negative plates on a Magnus 400 platesetter, the unload conveyor speed was much faster than the processor speed.
|
||
|
|
|||
Solution |
The first conveyor motor speed was set to 0.9. The second conveyor speed was set to 0.5. Lowering these values did not slow down the conveyor enough to match the processor speed. To match the unload conveyor speed with the processor speed, change the unload conveyor motor velocity from 2 Kp to 1 Kp. |
||
|
|
|||
Technical contact(s) |
|||
Submitted by |
|||
Date submitted |
23 Jan 2007 |
||