Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Recurring “Datapath error” appears on Magnus 400


Product

 
  • Kodak® Magnus™ 400
  • Kodak Magnus 400E
  • Kodak Magnus 200

Component

 

LIF data flow card


Error

 

Datapath error


Symptoms

 

A recurring nondescript Datapath error appears in the Magnus 400 Controller GUI, but does not include information about the error.

 


Cause

 

Interruption in the LIF data path


Solution

 

Before you replace the LIF data flow card, review the general log files to locate the reason for the datapath error.

In the following example, error 5736 describes a problem that occurred in the laser head because the temperature is not within the allowed range.

According to the information provided in the log, before you replace any parts:

  • Check the level of the LDA coolant.
  • Make sure that the air flow is not blocked on the chiller.

Technical contact(s)
 

Mario Amir

Submitted by
 

Mario Amir

Date submitted
 

25 Jun 2007


    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.