Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Upgrading a Magnus 400 E/Magnus 400 II E platesetter to a Magnus 400 S/Magnus 400 II S platesetter


Product

 
  • Kodak® Magnus™ 400 II E
  • Kodak Magnus 400 E

Background

 

This procedure describes how to upgrade from a Magnus 400 E functionality-limited configuration to a Magnus 400 S speed configuration with greater functionality.


Requirements

 
Part Number Description
518-03133A Kit, Magnus 400 Upgrade E to S includes:
  • Full media dongle
  • LDA S-type head
  • Loading tray assembly
  • Magnus 400 Controller 1.05.394
  • 651-00938A Xpo 3.2.41 for Magnus 400/Lotem 400 Xpose CD
    Note: For Magnus 400 configurations only. Do not install on Magnus 400 II configurations.
    518-03134A Kit, Magnus 400 II Upgrade E to S includes:
  • Full media dongle
  • LDA S-type head
  • Loading tray assembly
  • Magnus 400 Controller 1.05.394

  • Procedure

     

    This procedure includes the following sections:

    Before you begin

    1. In the Magnus 400 Controller software, send the carriage to position 750.
    2. Open the rear door.
    3. Quit the Magnus 400 Controller software, and shut down the platesetter.
    4. Open or remove the following:
      • Rear panel
      • Side doors
      • Side panels (on Magnus 400 platesetters only)
      • Unloading tray

    Upgrading the platesetter configuration

    1. Replace the LDA head.
    2. Remove the Magnus 400 E dongle.
    3. Install the Magnus 400 Full Media dongle.



    4. Install the loading tray.
    5. Reinstall the unloading tray.
    6. Reinstall the side and rear panels.
    7. Turn on the platesetter.
    8. Install the Kodak Magnus 400 Controller 1.05.394 software.
      Note: During the installation, in the Machine Type screen, in the Machine Type list, select Magnus 400S.



    9. (For Magnus 400 configurations only) Install the Kodak Xpo™ 3.2.41 software.
    10. Restart the Magnus 400 Controller software.
    11. In the Magnus 400 Controller software, go to Utilities > Hardware > Others > Magnus400. Right-click Magnus 400 and select Properties.
      1. In the Properties: Magnus 400 dialog box, double-click +MACHINE.
      2. In the Properties: Magnus 400\MACHINE dialog box, change the value of the following parameters, and then click Apply.
        • Change the Max Resolution to 140.
        • Change the Min resolution to 60.
      3. For your changes to take effect, restart the Magnus 400 Controller software.
    12. Calibrate and test the following:

    Technical contact
     

    Content owner: Alon Davidor
    See the Escalation page for escalation contacts.

    Date submitted
     

    10 Apr 2008


        Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.