This procedure includes the following sections:
Before you begin
- In the Magnus 400 Controller software, send the carriage to position
750.
- Open the rear door.
- Quit the Magnus 400 Controller software, and shut down the platesetter.
- Open or remove the following:
- Rear panel
- Side doors
- Side panels (on Magnus 400 platesetters only)
- Unloading tray
Upgrading the platesetter configuration
- Replace
the LDA head.
- Remove the Magnus 400 E dongle.
- Install the Magnus 400 Full Media dongle.
- Install the loading
tray.
- Reinstall the unloading tray.
- Reinstall the side and rear panels.
- Turn on the platesetter.
- Install the Kodak Magnus
400 Controller 1.05.394 software.
Note: During the installation, in the Machine Type screen, in
the Machine Type list, select Magnus 400S.
- (For Magnus 400 configurations only) Install the Kodak Xpo
3.2.41 software.
- Restart the Magnus 400 Controller software.
- In the Magnus 400 Controller software, go to Utilities > Hardware
> Others > Magnus400. Right-click Magnus 400 and select
Properties.
- In the Properties: Magnus 400 dialog box, double-click +MACHINE.
- In the Properties: Magnus 400\MACHINE dialog box, change the value
of the following parameters, and then click Apply.
- Change the Max Resolution to 140.
- Change the Min resolution to 60.
- For your changes to take effect, restart the Magnus 400 Controller
software.
- Calibrate and test the following:
|