Replacing the MSB_C
If the MSB_C is faulty in any way, you need to replace it.
- Shut down the Magnus 400 II system.
- Under the punch conveyor, unscrew the two flat-head screws that secure
the MSB cover to the MSB box, and set aside.
- Slide the faulty MSB out of the MSB box.
- Slide the new MSB_C into the MSB box.
- Reinstall the MSB cover.
Loading the MSB firmware
Important: Before you can load the MSB firmware,
you must perform a complete system shutdown.
- Shut down the Magnus 400 II system.
- Turn on the computer, but do not start the Kodak Magnus 400 Controller
software.
- On the desktop, double-click My Computer and go to C:\Magnus\Util\MSBMonitor.
- In the MSBMonitor folder, double-click HostMonitor.exe.
- In the HostMonitor dialog box, perform the following actions:
- Click Run script, and then double-click PlatesetterGoToBoot.txt.
The MSB script restarts and runs for approximately 30 seconds.
- Click Run script, and then double-click PlatesetterMsbFullDownloadNew_C.txt.
The script starts downloading will take approximately 15 minutes
to complete.
- After the script successfully downloads, turn off the platesetter.
- Turn on the Magnus 400 II system.
- Start the Magnus 400 Controller software.
- In Magnus Controller, go to Utilities > Hardware >Boards
and double-click MSB board.
- In the MSB Versions dialog box, verify that the following MSB firmware
versions appear:
| Component |
Version
|
| SW MSB |
1.1.1.42
|
| SW BOOT |
1.0.0.6
|
| FPGA MSB |
0.0.1.27
|
- Close the MSB Versions dialog box.
|