Home | Contact Us | Submit Troubleshooting Info | Search | Help
Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS
Product |
|
||
Machines affected |
Platesetter configurations with Dell® PE2900 workflow workstations |
||
Component |
Dell workflow workstation SCSI driver and board |
||
Symptoms |
During the exposure process, when a plate is not positioned correctly because of loading sequence failures or platesetter malfunction, a suspend error might occur. After the SCSI data starts transferring from the workstation to the MCE board, the MCE board aborts the plot, the SCSI data transfer stops, and the MCE board stops responding. When the MCE board stops responding, other side effects might occur, for example the GUI stops responding. |
||
Cause |
A known problem in the Adaptec 39U320 SCSI board installed on the PE2900 workstation. |
||
Solution |
Replace the Adaptec 39U320 SCSI board with an Adaptec 39U160 SCSI board. To update the 39U160 SCSI board driver on the Dell workflow workstation:
|
||
Technical contact(s) |
|||
Submitted by |
|||
Date submitted |
19 Jun 2007 |
||