Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Parameter value ranges for the Magnus 800 platesetter

Registry Parameters Value Range
Magnus800\Software systems\Device system\Device general params
Platesetter serial number   None
Type Magnus 800 None
Number of cassettes   3 - 5
Magnus800\Software system\Balance system\Weight actuator configuration
Weight actuator position (deg)   -109 - -113
Weight detector position (deg)   81 - 84
Magnus800\Software systems\Loading system\Parameters
d_DrumPositionOffsetForTEC   715 - 709

 

TMCE/Head Parameters Value Range
OTMCE>>Set Edge
Drumpos   52 - 57
Th2>>Set med 0
Strokewidth 224 None
Laserpower   15 - 18.5
Drumspeed    
Beamslope   -6 - 6
Beamcurve   -6 - 6
Sr   0.075 - 0.14
EdgeSr   0.011 - 0.14
Sd 0 None
recvrgain   7 - 3
OTMCE>>Set Gc
Mscale (ppm)   0 - -400
Mshift (microns)   57500 - 53500
mshiftsmall   57000 - 53000
Sscale (ppm)   0 - 350
Sshift (microns)   3600 - 2950
Orthoadjust   -140 - -380
Rotation   440 - -520
Rotationsmall   900 - -980
OTMCE>>Set gc trackprofile 1   120 - -120
OTMCE>>Set gc trackprofile 2   120 - -120
OTMCE>>Set gc trackprofile 3   120 - -120
OTMCE>>Set gc trackprofile 4   120 - -120
OTMCE>>Set gc trackprofile 5   120 - -120
OTMCE>>Set gc trackprofile 6   120 - -120
OTMCE>>Set gc trackprofile 7   120 - -120
OTMCE>>Set gc trackprofile 8   120 - -120
OTMCE>>Set gc trackprofile 9   120 - -120
OTMCE>>Set gc trackprofile 10   120 - -120
OTMCE>>Set gc trackprofile 11   120 - -120
OTMCE>>Set gc trackprofile 12   120 - -120
OTMCE>>Set gc trackprofile 13   120 - -120
OTMCE>>Set gc trackprofile 14   120 - -120
OTMCE>>Set gc trackprofile 15   120 - -120
OTMCE>>Set gc trackprofile 16   120 - -120
OTMCE>>Set gc trackprofile 17   120 - -120
OTMCE>>Set gc trackprofile 18   120 - -120
OTMCE>>Set gc trackprofile 19   120 - -120
OTMCE>>Set gc trackprofile 20   120 - -120
OTMCE>>Set gc trackprofile 21   120 - -120
OTMCE>>Set gc trackprofile 22   120 - -120
OTMCE>>Set mode 1
SscanResolution    
MscanResolution    
OTMCE>>Set mode 2
MscanResolution   1200 - 1270
SscanResolution   1200 - 1270
MscanDuplicate 2 None
SscanDuplicate 2 None
Th2>> set sys
serialnumber   None
Th2>> set foc
Offset   -50 - 50
OTMCE>> Set media 1
Name ThermalGold None
Invert 0 None
Extrascanlines 1 None
Type 9 None
Debrisoptions 3 None

 

 


    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.