Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Magnus Controller does not start when the JOIND Diagnostics software is running


Product

 

Magnus 800


Error

 

The following error message appears on the Magnus monitor:


Symptoms

 

An error message appears informing the user that Magnus Controller cannot start when the JOIND Diagnostics software is running.


Cause

 

Important: Magnus Controller does not currently support the JOIND Diagnostics software.

If the JOIND Diagnostics software is inadvertently started, a flag is created which notifies Magnus Controller that the JOIND Diagnostics software is running.
This prevents Magnus Controller from starting and instead the software generates an error message.


Solution

 

Do not run the JOIND Diagnostics software; it is not currently supported by Magnus Controller.

However, if the JOIND Diagnostics software is running, then perform the following actions:

  1. Open the Task Manager dialog box and make sure the JOIND Diagnostics software is not running.
  2. Delete the ~activeexe file from the Runtime folder:
    • Magnus Controller version 1.02.402:
      C:\Magnus\Diag\JServer\Runtime
    • Magnus Controller version 1.01.401:
      C:\Magnus\CompUDC\Allprj\Common\Bin\Debug\Diag\JServer\Runtime

Technical contact(s)
 

Yaron (Laurent) Dellus

Submitted by
 

Yaron (Laurent) Dellus

Date submitted
 

01 Mar 2006