Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Preventing the safety loop from being intermittently activated on Magnus 800 devices


Product

 

Magnus 800 devices


Component

 

Bypass switches


Error

 

The safety loop on all Magnus 800 devices is intermittently activated.


Symptoms

 

Magnus 800 devices intermittently stop for no apparent reason.


Cause

 

If a Magnus 800 device contains a badly assembled bypass switch, then the device may stop for no apparent reason.


Solution

 

Check the bypass switches and make sure that the four screws securing the switches’ top block are fully tightened.



Important: Do not apply Loctite 242 adhesive to the screws because the adhesive will damage the plastic bypass switches.


Technical contact(s)
 

Itai Peperovich

Submitted by
 

Itai Peperovich

Date submitted
 

13 Mar 2006


    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.