Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Debris disconnected - Error occured: 43014
[DEB:The debris hose is disconnected, the cabinet has lost power, or the cabinet lid is not latched properly]


Product

 
  • Magnus VLF
  • Magnus VLF MCU
  • Magnus VLF CL

Machines affected

 

All


Component

 

Universal Debris Removal Cabinet (UDRC)


Error

 

43014: The debris hose is disconnected, the cabinet has lost power, or the cabinet lid is not latched properly


Symptoms

 

The debris removal system does not respond. Note: There is no serial control cable to the UDRC, only an on/off signal sent via K2 control.


Cause/Solution

 
  • Fuse blown (F1/F2). Replace CB3 breaker.
  • Power cable disconnected at bulkhead near debris cabinet. Reconnect the cable.
  • No line power (line 2) to debris/MCU (if installed). Connect power to line 2.
  • Lid not closed (switch problem) - signal is fed to the Lionel 0 board. Check that lid is closed and that the switch is working.
  • K2 relay has failed. Replace relay.

Technical contact(s)
 

Micle Zisman

Submitted by
 

Christopher St.Louis

Date submitted
 

31 Dec 2004


    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.