RCON Interface:Received invalid command code from workstation (Error 34810)


Product

  All GMCE devices.

Error

 

Error 34810 - RCON Interface:Received invalid command code from workstation.


Symptoms

 

When booting up the output device, the GMCE will not go beyond boot mode. Resetting does not help.


Cause

 

The NVS file (GMCENVSxx.bin) is corrupt.


Solution

 

Replace the GMCENVSxx.bin file with a backup.


See also

 

GMCE Firmware and LED Reference.


Technical contact(s)
 

Christopher St.Louis