Home | Contact Us | Submit Troubleshooting Info | Search | Help
Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS
Product |
All Magnus VLFs | ||
Error |
Suspended: 40639 |
||
Symptoms |
Intermittent balance weight position error and TMCE/GMCE intermittently resetting. |
||
Cause |
The balance weight sensor cables are tied to the TEC/LEC & roller air tubes that move with the backbone assembly. Over time, the movement of the backbone wiggles the balance weight sensor cables back and forth until they develop breaks in the cable. These cable breaks may also be sending spikes to the TMCE/GMCE causing it to reset. |
||
Solution |
Replace the damaged cables and reroute them so that there is no movement of the cables and so that they do not interfere with other components.
|
||
Technical contact(s) |
|||
Submitted by |
|||
Date submitted |
31 Jul 2007 |
||