Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Error: 45242 Warning [Product1:Chiller flow is too low (Chiller flow sensor)]


Product

  All Magnus VLFs

Error

 

Error: *** Unsolicited Message 45242 Warning [Product1:Chiller flow is too low (Chiller flow sensor)].


Symptoms

 

The warning is reported on the Service Shell monitor. The TH3 head also shuts down when the error is reported.


Cause/Solution

 

The chiller flow switch is reporting that the coolant flow is too low. The head power is automatically switched off to prevent overheating. This could be caused by a chiller failure, low coolant pressure, a faulty switch, or faulty switch wiring. See chiller troubleshooting. The replacement switch kit is 510-00048A.


Technical contact(s)
 

Al Edge

Submitted by
 

Rick Hsu

Date submitted
 

11 Sep 2007


    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.