Home | Contact Us | Submit Troubleshooting Info | Search | Help
Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS
Product |
All Magnus VLFs | ||
Error |
Error: |
||
Symptoms |
The warning is reported on the Service Shell monitor. The TH3 head also shuts down when the error is reported. |
||
Cause/Solution |
The chiller flow switch is reporting that the coolant flow is too low. The head power is automatically switched off to prevent overheating. This could be caused by a chiller failure, low coolant pressure, a faulty switch, or faulty switch wiring. See chiller troubleshooting. The replacement switch kit is 510-00048A. |
||
Technical contact(s) |
|||
Submitted by |
|||
Date submitted |
11 Sep 2007 |
||