Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Unexpected plate at processor - error 45902
MDHEJECT: No plate was expected to be at the processor but one was found. Check for processor malfunction.


Product

 
  • Magnus VLF MCU
  • Magnus VLF CL

Machines affected

 

All


Error

 

45902: MDHEJECT: No plate was expected to be at the processor but one was found. Check for processor malfunction.


Symptoms

 

As the plate is being fed into the processor by the ejector, this error can occur. On eject, the plate will bounce up and down.


Cause

 

Depending on the height of the processor and the size of the plate, the plate can lift off the optical sensor at the end of the bridge during the eject sequence. The MCE will see the plate off the bridge and when the plate falls back on the bridge, this error can occur.


Solution

 

The plate processor height must be between 95 mm(37.4 in.) to 102 mm(40.1 in.).


Technical contact(s)
 

Micle Zisman

Submitted by
 

Christopher St.Louis

Date submitted
 

31 Dec 2004