Home | Contact Us | Submit Troubleshooting Info | Search | Help
Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS
Product |
|
||
Machines affected |
All |
||
Error |
45902: MDHEJECT: No plate was expected to be at the processor but one was found. Check for processor malfunction. |
||
Symptoms |
As the plate is being fed into the processor by the ejector, this error can occur. On eject, the plate will bounce up and down. |
||
Cause |
Depending on the height of the processor and the size of the plate, the plate can lift off the optical sensor at the end of the bridge during the eject sequence. The MCE will see the plate off the bridge and when the plate falls back on the bridge, this error can occur. | ||
Solution |
The plate processor height must be between 95 mm(37.4 in.) to 102 mm(40.1 in.). | ||
Technical contact(s) |
|||
Submitted by |
|||
Date submitted |
31 Dec 2004 |
||