# 40312 - MCU move timeout: Failed to arrive at sensor


Product

 

Magnus VLF MCU


Component

 

Multi-Cassette Unit.


Error

 

40312 MDHBAY:MCU move timeout: Failed to arrive at sensor.


Symptoms

 

This error occurs when you try to move the MCU to the cassette load position to install a new cassette.


Cause

 

The NVS settings for the bay are set incorrectly. The last state of the device when leaving integration was not changed after the cassettes were removed from the MCU.


Solution

 

Set the install bit for each bay to zero. Type set bay 1 CassetteInstalled 0 (bay 1, 2, 3, and 4).
Install the cassettes. Type cassette load 1 for each bay (1, 2, 3, and 4). Make sure you set bay x CassetteInstalled back after each load.


Technical contact(s)
 

Micle Zisman

Submitted by
 

Chris St. Louis

Date submitted
 

15 Mar 2006