# 40828 - Unload table plate deflector flap is obstructing the backbone


Product

 

Magnus VLF Autoloaders


Component

 

Unload table


Error

 

The unloadtable plate deflector is obstructing the backbone. For two-position or three-position backbones, the plate deflector must be sensed before the backbone can be safely moved to a forward position.


Causes/Solutions

 
  • Plate deflector missing. Check for plate deflector.
  • Plate deflector improperly seated. Check plate deflector seating.
  • Faulty sensor. The sensor itself can be damaged and need to be replaced or the tab that goes into the sensor is bent.
     

Technical contact(s)
 

Micle Zisman

Submitted by
 

Micle Zisman

Date submitted
 

25 May 2006


    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.