Home | Contact Us | Submit Troubleshooting Info | Search | Help
Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS
Product |
Magnus VLF CL | ||
Component |
Safety circuit |
||
Error |
35780: Emergency off fuse (SY_&AbortFuse) not detected. |
||
Cause/Solution |
Cause: Fuse F8 on the PDB triggered due to a short in the cable ground wire.
Solution: Check if there is a pinched cable in the line—the cable goes from PDB J42 to the ESS on the shoulder away panel, to other ESS switches, and finally to CL plug. Also check the voltage on J42, pin 1. With the cable plugged in it should be zero. With the cable unplugged, (wait 20-25 sec for polyfuse to reset) it should be 24V. |
||
Technical contact(s) |
|||
Submitted by |
|||
Date submitted |
28 Aug 2006 |
||