Home | Contact Us | Submit Troubleshooting Info | Search | Help
Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS
Device |
Magnus VLF MCU | ||
Component |
Slip sheet removal (SSR) bin | ||
Error |
Excessive static | ||
Symptoms |
Operators report getting shocked by touching the SSR bin handle and possibly the cassettes when reloading. | ||
Cause/Solution |
Cause: Static build-up during the automatic SS removal process due to improper grounding of the SS bin area.
Solution: Check the grounding cable, the contact bracket on the MCU and the contact plate mounted of the back of the removable SS Bin.
|
||
Practical cases |
Operators at a site were reporting excessive amounts of static discharge into their hand as they tried to remove the SS bin from the system. The problem was quite pronounced and was decribed as follows: “It was like a tazer gun going off. The arc was an inch long and could be heard 10 feet away” | ||
Technical contact(s) |
Chris Bradley | ||
Submitted by |
Chris Bradley | ||
Date submitted |
24 Oct 2006 | ||