Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Unsolicited Message 45243 Warning [Product1:Head Power Module safety circuit failure]


Product

 

Magnus VLF with TH3


Component

 

Safety circuit and PDB.


Error

 

Unsolicited Message 45243 Warning [Product1:Head Power Module safety circuit failure]


Symptoms

 

The TH3 remaines online even if a door is open, and/or the chiller flow switch is disconnected.


Cause

 
  • The relay on the PDB that turns off PS3 when the safety loop opens can be stuck on. In this condition PS3 continues to provide power to TH3.
  • The coolant flow switch may be defective.


Solution

 
  • Easy tapping on the relay may release the contacts, but the permanent solution is to replace the PDB (p/n 10-4112J).
  • Replace the chiller flow switch (p/n 510-00048A).

Technical contact(s)
 

Micle Zisman

Submitted by
 

Ciprian Nistor

Date submitted
 

05 Dec 2007