Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Field Change Order C967


Applies to
Thermoflex
Component TFX Head / Debris Removal System
Problem The previous debris removal nozzle was difficult to set up and had too many components. During machine operation and maintenance there was potential for damage to the window and the debris removal system (from plate fly-off), and for accidental misalignment. The design also did not incorporate a method for keeping the window clean.
Solution A new debris nozzle has been designed which does not need adjustment or maintenance. This ECO covers implementation of the new debris removal nozzle with Morgan cabinets.
Procedure Upgrade Procedure: Upgrade TFX DR Nozzle w/Morgan Cabinet .
Parts Needed Upgrade Kit: 05-0245
Release Date October 11, 2001
Priority Next Visit
Contact Gary Edge