Home | Contact Us | Submit Troubleshooting Info | Search | Help
Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS
| Applies to: | ThermoFlex | Priority = Next visit |
| Reason = solve problem of hose popping out | ||
| Release date = 14 Dec, 1999 | ||
| Machines affected | All | |
| Component | Engine | |
| Description | Debris hose does not stay in the hose trough when the carriage returns to home following a large plot. Because the debris hose is much stiffer than the cooling hose flex conduit, and the present configuration has the bend of the debris hose lying inside the bend of the cooling hose flex conduit, the two tend to become crossed up, and together they are too wide to fall back into the hose trough. | |
| Parts needed | 1 of 50-1953A (ASSY,MECH,DEBRIS REMOVAL HOSE,FX1) | |
| Procedure | The solution is to reverse the positions of the debris hose and the cooling hose flex conduit (valid for both TFX and 1.7 heads). | |
| Action Required |
|
|
| Date submitted | 14 December, 1999 | |