Home | Contact Us | Submit Troubleshooting Info | Search | Help
Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS
Product |
| ||
Machines affected |
All |
||
Component |
Drum Vacuum Drive Inverter |
||
Error |
Display on Inverter shows External Fault 4 (EF4) |
||
Solution |
The EF4 fault appears if the thermistor in the drum vacuum pump has gone open circuit (ie indicating the pump is overheating), or if there is a break in the wiring to the thermistor.
This error may also occur due to bad programming. Check parameter n038 to ensure it is set to External Fault (NC).
This parameter tells the inverter what to do when an open circuit condition occurs between terminals SC and S4; in this
case, trigger a fault condition.
|
||
See also |
|
||
Technical contact(s) |
|||
Submitted by |
|||
Date submitted |
04 Jun 2004 |
||