Home | Contact Us | Submit Troubleshooting Info | Search | Help
Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS
Applies to |
ThermoFlex |
|---|
Machines affected |
All |
|---|
Error number |
n/a |
|---|
Component |
Drum Vacuum Pump |
|---|
Problem |
The Drum Vacuum Pump (DVP) has an internal cooling fan to cool the pump motor. Failure of this fan could affect the operation of the DVP. |
|---|
Symptoms |
Fan not working. |
|---|
Causes and |
No power is supplied to the fanPossible causes:· Blown fuse,· faulty transformer,· Drum Vacuum Drive is incorrectly programmed - power not switched to the fan, capacitor blown. Remove the DVP cover to access the Junction Box. Refer to the sticker (74-3246A) inside the junction box and inspect for any loose wiring.Unless otherwise stated, perform the following tests with the pump running:
Programming the Inverter drive:
|
|---|
See also |
|---|
Technical contact |
Ted Nivolianitis |
|---|
Date submitted |
09 December, 1999 |
|---|
Date modified |
14 February, 2000 |
|---|