Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Dot gain is out of specification

Applies to

ThermoFlex

Machines affected

All

Error number

Component

Media

Problem

Dot gain has gone out of specification

Symptoms

Dot gain measurement is not correct

Causes and
Solutions

Check the following possible causes for the dot gain being out of specification:
  • The Volcano power setting under "set med #" should be 350 for all the stroke values.
  • Make sure that when you type "sys info" that hold power should be set to off.
  • Check laser output : "ld all 500 mw" to set all diodes to 500 mw, then "dps raw range" should output a string of numbers that we can compare to previous output values. Make sure the laser is not on any media when it does this.
  • Check to make sure that "set hdm # ds" and "set med # drumspeed" are set to 225.

See also


Technical contact

Biljana Basiljevic

Date submitted

28 March, 2000

Date modified

26 April, 2000