Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Surface reflectivity is wrong

Applies to

ThermoFlex

Machines affected

All

Error number

-

Component

Media

Problem

Surface Reflectivity is wrong

Symptoms

Workstation serial communications: ok
Active Images:
Image ID: 4 Load Started, Image task state is 3
SUSPENDED: Autoloader2: Focus laser saturated, Please check media surface reflectivity is correct
SCSI Initiator 7: transfer period = 0x4, transfer offset = 0x8
SCSI state is currently 1
Plate locations: 
Drum: Active

Causes and
Solutions

Media is loaded upside down.

Load media the right way up.
Note: If media is loaded upside down and the head actually images, it will transfer the film emulsion onto the drum permanently. This will cause reflective artifacts on flexo plates imaged after that.


See also


Technical contact

Biljana Basiljevic

Date submitted

28 March, 2000

Date modified

26 April, 2000