Home | Contact Us | Submit Troubleshooting Info | Search | Help
Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS
Applies to |
ThermoFlex |
|---|
Machines affected |
All |
|---|
Error number |
- |
|---|
Component |
Media |
|---|
Problem |
Surface Reflectivity is wrong |
|---|
Symptoms |
Workstation serial communications: ok Active Images: Image ID: 4 Load Started, Image task state is 3 SUSPENDED: Autoloader2: Focus laser saturated, Please check media surface reflectivity is correct SCSI Initiator 7: transfer period = 0x4, transfer offset = 0x8 SCSI state is currently 1 Plate locations: Drum: Active |
|---|
Causes and |
Media is loaded upside down. Load media the right way up. |
|---|
See also |
|---|
Technical contact |
Biljana Basiljevic |
|---|
Date submitted |
28 March, 2000 |
|---|
Date modified |
26 April, 2000 |
|---|