Home | Contact Us | Submit Troubleshooting Info | Search | Help
Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS
Description | Location | NVS Parameters |
Parts | Procedures
The Filter/regulator assemblies regulate, filter, and dry the customer's compressed air supply.
Clogged filters can cause air pressure problems resulting in dropped plates by the plate picker in automatic machines. Filter failure can also damage the device's air system and allow contaminants to enter the device.
Note: It is critical for long-term performance of the device that
the filters be changed at specified intervals.
For filter parts, see Replacement Filters.
Magnus VLF | ThermoFlex Wide | ThermoFlex Wide II | Trendsetter VLF | Trendsetter VLF AL | VLF Platesetter
- 2-Stage Filter Regulator System
- Trendsetter VLF—500-03242A BOM | DWG (from B1083 and up)
- ThermoFlex Wide—500-03344A BOM | DWG
(from FX86 and up)- Replacement Filters - see
- 3-stage Filter Regulator System (old style)
- Filter bowl, auto drain—55-0690
- Filter bowl, manual drain—55-0694
If Series 1 filter/regulator parts are no longer available, replace with whole assembly with 500-02469B.
| Item | Stored Service Parts | Reference | Notes/photos |
|---|---|---|---|
| Filter regulator assembly | 500-02469A | ||
| Filter kit | 328-00001 | ||
| Filter bowl | 55-1280 | ||
| Silencer | 55-1271 | ||
| Air pressure gauge | 342-00067 | ||
| Regulator | 334-00118 |
Magnus VLF devices that were manufactured as series 2 devices include the following: MT149, MT150, and MT159 onwards with the exception of MT164.
| Item | Stored Service Parts | Reference | Notes/photos |
|---|---|---|---|
| Filter regulator assembly | 500-02469B | BOM | DWG | |
| Filter kit | 328-00001 | ||
| Filter bowl | 55-1280 | ||
| Micro-mist filter
Replacement cartridge |
332-00025
332-00028 |
500-02469 item 60 | |
| Silencer | 55-1271 | 500-02469 item 20 | |
| Air pressure gauge | 342-00067 | 500-02469 item 120 | |
| Regulator | 334-00118 | 500-02469 item 80 |
For Magnus VLFs with a TH3, a slight hissing sound can be heard coming from the filter/regulator assembly's compressed air dryer. This sound is normal and is caused by air being purged from a small hole in the tube to expel moisture.
| Item | Stored Service Parts | Reference | Notes/photos |
|---|---|---|---|
| Filter regulator assembly | 500-02470C | BOM | DWG | |
| Filter kit | 328-00001 | ||
| Filter bowl | 55-1280 | ||
| Micro-mist filter
Replacement cartridge |
332-00025
332-00028 |
500-02469 item 60 | |
| Silencer | 55-1271 | 500-02470 item 20 | |
| Air pressure gauge | 342-00067 | 500-02470 item 120 | |
| Regulator | 334-00118 | 500-02470 item 80 | |
| TH3 pneumatic filter assembly | 500-03794B | BOM | DWG | Contains adsorption filter, micro-mist filter, and regulator |
| Adsorption filter assembly | 332-00015 | 500-03794 item 40 | For replacement filter, order filter kit 332-00027 |
| Micro-mist filter assembly | 332-00016 | 500-03794 item 50 | For replacement filter, order filter kit 332-00027 |
| TH3 pneumatic replacement filter kit | 332-00027 | Always replace both filters if one needs to be replaced | |
| Regulator | 55-0648 | 500-03794 item 130 | |
| Pressure switch | 172-00064 | 500-03794 item 30 |
For other replacement Filters - see Magnus VLF Replacement Filters
See maintenance procedures in Operator Manuals.
See also Manufacturers precautions.