Spindle Cam Locks Rotate too far


Product

 

ThermoFlex Wide II


Machines affected

 

All


Error

 

The spindle cam locks rotate a full revolution before the torque wrench reaches full torque.


Cause

 

With time, the contact points of the cam locks wear and may result in the camlock rotating a full revolution before the torque wrench reaches full torque.


Solution

 
  1. Identify the cam lock pin on the drum or arbor that matches the spindle cam lock that is rotating too much.
  2. Remove the screw that prevents the camlock pin from rotating using a ¼” Allen key.
  3. Rotate the cam lock pin one revolution into the drum or arbor and install the anti-rotation screw.
  4. Reinstall the drum or arbor into the spindle and confirm that the full torque can be reached with the torque wrench.

Technical contact(s)
 

Gary Edge

Submitted by
 

Bob Magyar