Product |
|
ThermoFlex Wide II |
|
Machines affected |
|
All |
|
Error |
|
The Tailstock will not disengage from the drum.
|
|
Cause |
|
- The drum hoist is not raised
- The drum hoist is poorly adjusted
- The tailstock lock cylinder is not retracted
- There is no lubrication between the red bushing of the retraction linkage and the 40mm main support rod
- The bushing is seized onto the end of the drum pin
|
|
Solution |
|
- Confirm that the drum hoist is adjusted properly and raised.
- Visually check that the lock cylinder has been retracted by looking in between the base of the tailstock and the tailstock itself.
- Add a small amount of spray lubrication to the linkage bushing on the support rod to free the tailstock.
- If the tailstock still fails to release, the tailstock bushing may be seized to the drum pin. Contact the response center for further instruction.
|
|
Technical contact(s) |
|
Gary Edge |
Submitted by |
|
Bob Magyar |
Date submitted |
|
10 Oct 2003 |