Head Collides with the Garage or Arbor


Product

 

ThermoFlex Wide II


Machines affected

 

All


Error

 

The Head collides with the side of the Garage block or Arbor.


Cause

 
  • The side-looking sensor on the debris removal nozzle fails.
  • The carriage stage does not return to the home position before receiving instruction to move to the park (garage) position.
  • The garage block is bent out of shape from a previous collision.
  • The firmware is causing the error.

Solution

 
  • Confirm that the side-looking sensor is functioning properly.
  • Confirm that the home tab of the carriage stage is properly adjusted.
  • Confirm that the garage block is in good shape.
  • Confirm that the firmware is instructing the carriage stage to be fully back before moving the carriage to the park position.