Product |
|
ThermoFlex® Wide II with Sleeve Device |
|
Component |
|
Production hub |
|
Symptoms |
|
The production hub cannot rotate to interface with the ThermoFlex device or premounter. |
|
Cause |
|
- The rotational stop pin in the production hub base is incorrectly positioned.
- There is insufficient lubrication on the production hub shaft.
|
|
Solution |
|
Cause 1
- Remove the two rubber bumpers from the top plate at the front of the hub and remove the carriage from the hub.
- With an assistant, lift the production hub straight up and off the base.
- Note the position of the rubber bumper stop on the underside of the production hub and position the spring-loaded rotational stop pin correctly.
- Replace the production hub in the base, and replace the carriage and rubber stops.
Cause 2
- Remove the two rubber bumpers from the top plate at the front of the hub and remove the carriage from the hub.
- With an assistant, lift the production hub straight up and off the base.
- Note the position of the rubber bumper stop on the underside of the production hub.
- Remove any corrosion or scratches with emery paper and lubricate the shaft with a light coating of grease.
- Replace the production hub in the base, and replace the carriage and rubber stops.
|
|
See also |
|
Installation Procedure - Sleeve Options
|
|
Technical contact(s) |
|
Dal Wagner |
Submitted by |
|
Zane Pfrimmer |
Date submitted |
|
29 Jul 2004 |