Problem loading half size thick plates


Product

 

ThermoFlex® Wide II


Symptoms

  When loading a half size thick plate (for example: 2000 mm x 700 mm x 4.7mm), the drum will not move to the leading edge position once the trailing edge has been taped.

Cause

 

Because the drum is not yet balanced due to the plate format, the drum has difficulty stabilizing and will not move when the down switches are pressed.


Solution

  Increase the parameter DRUM ICTS from 5 to 9 and reset the device.

Technical contact(s)
 

Yoel Guttmann

Submitted by
 

Frederic Mayot

Date submitted
 

20 Jun 2005