Home | Contact Us | Submit Troubleshooting Info | Search | Help
Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS
Product |
ThermoFlex® Wide II |
||
Symptoms |
When loading a half size thick plate (for example: 2000 mm x 700 mm x 4.7mm), the drum will not move to the leading edge position once the trailing edge has been taped. | ||
Cause |
Because the drum is not yet balanced due to the plate format, the drum has difficulty stabilizing and will not move when the down switches are pressed. |
||
Solution |
Increase the parameter DRUM ICTS from 5 to 9 and reset the device. | ||
Technical contact(s) |
|||
Submitted by |
|||
Date submitted |
20 Jun 2005 |
||