Home | Contact Us | Submit Troubleshooting Info | Search | Help
Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS
Product |
Kodak® ThermoFlexWide II |
||
Component |
Z-stage |
||
Symptoms |
TFX head cannot be focused |
||
Cause |
Z-stage is not in the correct position. |
||
Solution |
The Thermoflex Wide II Z-stage must be in the correct position before the TFX head can be properly focused. Use the Manually Zeroing the TFX Head to a Plate or Sleeve procedure to correctly calculate the Z-stage position to overcome TFX head zeroing problems. |
||
Technical contact(s) |
|||
Submitted by |
|||
Date submitted |
07 May 2008 |
||