Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Drum Initialization Times Out and "Drum motor goto speed fails" Error Message Appears on ThermoFlex Narrow


Product

 
  • Kodak® ThermoFlex® Narrow
  • ThermoFlex Narrow Hybrid

Component

 
  • Interlock relay
  • D-box
  • MCF board
  • Laser interlock

Error

 

Drum motor goto speed fails


Symptoms

 

The drum initialization task times out, an alarm sounds when the doors are opened, and an error message appears.


Cause

 

One of the following components:

  • Interlock relay
  • D-box
  • MCF board
  • Laser Interlock
  • Software installation

Solution

 
  1. Open the inner panel of the D-box above the interlock board and verify that the yellow interlock relay is plugged in.


  1. Verify that the D-box supplies the following power, and if it does not, replace the D-box.
    • To the E-box: Over 200 V AC
    • Phase to GND: 120 V AC
    • Phase to phase: 210 V AC
  2. Replace the MCF board.
  3. Replace the laser and mechanical interlock housing.
  4. Reinstall the software.

Test

 

Expose a job.


Technical contact(s)
 

Viki Arviv

Submitted by
 

Louie Sutherland

Date submitted
 

16 Nov 2006