Side-to-Side Detector Status Appears Incorrectly on ThermoFlex Narrow Hybrid With Offset Option


Product

 

Kodak® ThermoFlex® Narrow Hybrid platesetter with the Offset option


Component

 
  • Side to side detector
  • MCF board

Symptoms

 

In the ThermoFlex Controller software, the side-to-side detector status appears incorrectly. It displays OFF when pins are in the drum, and ON when pins are not in the drum.


Cause

 
  • Side-to-side detector is not properly adjusted
  • Side-to-side detector is malfunctioning
  • MCF board is malfunctioning

Solution

 

Status does not change to OFF for any of the pins:

  • Check the side-to-side filter color. If the filter is not blue, replace the sideߛtoߛside detector.
    Note: The new side-to-side detectors do not have the blue filter installed, so you must install the filter.

Status changes to OFF for side pins but not for center pins:

  1. Insert a registration pin in the center registration pin hole, and rotate the drum so that the registration pin is aligned with the side-to-side detector.
  2. On the right (transmit) side, open the side-to-side detector screw and manually move the side-to-side detector back and forth to see if it detects the pin.
    • If the pin is detected, tighten the two screws.
    • If the pin is not detected:
      1. Tighten the two screws shown above.
      2. Turn the sensitive screw shown below in both directions to see if the pin is detected.
      1. Replace the side-to-side detector and repeat the test.
      2. Replace the MCF board.

Test

 

Confirm that the status in the Drum Side To Side Detector dialog box is correct.


Technical contact(s)
 

Viki Arviv

Submitted by
 

Viki Arviv

Date submitted
 

16 Nov 2006