Home | Contact Us | Submit Troubleshooting Info | Search | Help
Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS
| Applies to | Trendsetter NEWs | Priority = Next Visit
Reason = Safety Release date = 26 Oct 2001 |
|
Machines affected |
All Trendsetter NEWs machines with TEH 2 heads | |
|---|---|---|
|
Component |
TEH 2 power cables | |
| Problem | Existing cable does not have proper reinforcement on the insulation for high voltage application (higher than 30V) nor do they have the proper safety agency approval. | |
| Solution(s) | Replace 10-4954A with 10-4954B. Mark #9 on the 100 label. | |
| Parts needed | ||
| Tools needed | ||
| Procedure | ||
| See also | ||
| Technical contact | Simon Cheung | |
| Date submitted | Oct 2001 | |