Trendsetter NEWS 200: One of the two TH2 thermal heads fails


Product

  Trendsetter® NEWS 200

Symptoms

  Master or slave TH2 head fails

Cause

  See the Thermal 2 Head site’s Troubleshooting page for symptoms and causes of thermal head failure.

Solution

 

Replace the failed TH2 head as soon as possible.

Note: Until the failed head has been replaced, the NEWS 200 output device will be hard down. At this time, there is no way to make the NEWS 200 image plates using only one thermal head.


Technical contact
 

Jack Miro

Submitted by
  Jack Miro
Date submitted
  13 Jul 2005