Home | Contact Us | Submit Troubleshooting Info | Search | Help
Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS
|
|
||
Product |
Trendsetter® NEWS 200 | |
|
|
||
Symptoms |
Master or slave TH2 head fails | |
|
|
||
Cause |
See the Thermal 2 Head sites Troubleshooting page for symptoms and causes of thermal head failure. |
Solution |
Replace the failed TH2 head as soon as possible. Note: Until the failed head has been replaced, the NEWS 200 output device will be hard down. At this time, there is no way to make the NEWS 200 image plates using only one thermal head. |
|
|
||
Technical contact |
||
Submitted by |
Jack Miro | |
Date submitted |
13 Jul 2005 | |