| Component |
|
||||||||||||||
| Problem |
The Motorola pressure sensors used on previous versions of the TEE board are being discontinued. The new TEE board uses the new MPX5000 series sensors, which have lower offset values than the older sensors. Note: Version B and C boards have the same functionality - the reason for the version change is mostly because the board layout has changed for version C. See 10-3627C assembly drawing. |
||||||||||||||
| Solution |
When replacing a previous version TEE board with the new "C" version, recalibrate the pressure sensors. Note: To recalibrate the sensors accurately (and
easily), you may need to upgrade the device firmware to a version that
supports the |
||||||||||||||
| Procedure |
Ensure that the output device is running at least the following firmware version:
After replacing the TEE board, set the SIO keyswitch to the Laser Hazards position, and use the following procedure to calibrate the pressure sensors:
Additional Procedures for Spectrum, TS Autoloader, and TS 2637 If the output device is a Spectrum, calibrate the vacuum sensors, as described in the “Setting Drum Vacuum and Vacuum Roller Suction Thresholds” section of the Spectrum Trendsetter 3244 Common Startup Procedure .If the device is a Trendsetter 2637 or Trendsetter Autoloader, set the picker vacuum threshold and the unload vacuum threshold to the correct values. For the 2637, you will also need to set the unload vacuum threshold dual parameter. |
||||||||||||||
| Parts Needed | TEE board 10-3627C | ||||||||||||||
| Release Date | 14 Jun 2000 | ||||||||||||||
| Priority | On failure | ||||||||||||||
| Action Required | Install new TEE board, upgrade base Trendsetter firmware to version 2.40 or later (if necessary), and calibrate the pressure sensors. |