Field Change Order #E114

 

Applies to
  • TS3244 (TS8 based)
  • Trendsetter Proofsetter
  • TS2637
  • TS3230(TS4)
Priority = N/A
Reason = Manufacturing
Release date = April 2001

Machines affected

Implemented, beginning at serial number
  • TE242 - Trendsetter
  • PX072 - Proofsetter
  • All newspaper machines

100 Label change # 12 on TS8 and #5 on TS2637

Components

  • Power Box
  • SCSI cable
Problem
  • Have two versions of power boxes (11-0603 & 11-0872) in production: one for Base & Spectrum and one for Autoloader & TS2637.
  • The shielded ribbon SCSI cable is unreliable.
Solution(s)
  • Standardize on one version of power box, 11-0872.
  • Equip TS8 manual load engine (#50-1672A) with a high-speed drum motor and stepper carriage motor.
  • Introduce new internal molded SCSI cable 10-4057B

NOTE: Machines ship with Firmware version 2.51b with the following NVS Changes.

Parts needed To replace SCSI cable:

Upgrade kit 05-0219 BOM

Tools needed N/A
Procedure To change SCSI cable:
  1. Remove 2 hex screws (J15) on non-connector side of backplane (10-4298) that hold SCSI cable on the board.
  2. Remove old SCSI cable (10-4057A).
  3. Plug new SCSI cable (10-4057B) into J15.
  4. Attach spacers and screws provided in the upgrade kit. See Insert A on Drawing 10-4298AB. Spacers go on connector side of board.
Technical contact Simon Cheung