| Applies to |
|
Priority = Next Failure
Reason = Reliability Release date = May 2001 |
|
Machines affected |
|
|
|---|---|---|
|
Component |
TEC backbone | |
| Problem | The current TEC backbone uses reed switches that are unreliable. | |
| Solution(s) | Replace the reed switches with microswitches (#15-3478). | |
| Parts needed | Field Upgrade Kit:
NOTE: Effective 1 March, 2002 a new longer cable #10-4947B is shipping with these kits, either in addition to the kit or as a part of it. Be sure to install the longer cable when doing the upgrade. |
|
| Tools needed | Metric allen wrenches | |
| Procedure | Procedure TS4 based machines
|
|
| Action required | Mark 100 Label # 13 on TS8, #28 for TS3, TS3/8 and #5 on TS NEWS | |
| Technical contact | Darcy Priest | |
| Modified by | Steve Froese | |
| Date modified | 1 Mar 2002 | |