Home | Contact Us | Submit Troubleshooting Info | Search | Help
Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS
Replaces the desiccant box with a dehumidifier unit.
| Applies to |
|
Priority = Next Failure
Reason = Reliability Release date = Aug 2001 |
|
Starts with |
Shipment of new machines with the dehumidifier installed began with TE322 (Trendsetter 3230/3244) and PX085 (Trendsetter Proofer). | |
|---|---|---|
|
Component |
Head and desiccant box. | |
| Problem | Existing dehumidifying methods are high maintenance. | |
| Solution(s) | Discontinue desiccant systems. Replace with dehumidifier systems that provide clean dry air to slightly pressurize (0.05 tp 0.5" WG) the optical cavity. | |
| Parts needed | Kit #05-0244. BOM
Note: This kit number has been updated to reflect the changes in ECO E453. |
|
| Tools needed | See Dehumidifier Unit (DHU) Installation Procedure | |
| Procedure | ||
| Action required | Mark the 100 label as follows:
|
|
| Technical contact | Dan Williams | |