Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Field Change Order #E312

 

Applies to Trendsetter NEWS/3230/3244 All options                     Priority =Next Visit
Reason = Reliability
Release date = 01 Sept 2001

Machines affected

All Trendsetters built from 1997 to 01 Sept 2001

Component

Load ramp sensor
Problem The load ramp sensor (#36-3141) currently used on Trendsetters has an incorrect focal length.
Solution(s) Replace with sensor with correct focal length.
Parts needed Replacement sensors #36-3210
Tools needed n/a
Procedure

Check this photo to see if replacement is necessary. The part number on the microswitch is key to identifying old and new.
 

Machines do NOT require the new optical sensor if they have either of the following sensors:

  • optical sensor mounted on a PC Board (found in very early Trendsetters)
  • ALEPH sensor - best identified by the absence of a resin seal on one side of the sensor

The sensors that DO require replacing are the SHARP optical sensors. They look identical to the ALEPH except for the presence of a resin seal on the edge nearest the connector. Remove this sensor and replace with 36-3210 on next visit.

NOTE: other sensors using the same part, such as the load table and unload pan on the Trendsetter Autoloader, can wait until failure for replacement.

Technical contact Steve Froese

    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.