Restricted parameter, insufficient access level (MCE Error number 34039)


Product

 

MCE firmware


Error

 

Restricted parameter, insufficient access level (MCE Error number 34039)


Symptoms

 

This error message may appear when you use the command set media n name <NewMedia>.


Cause

 

Special access is required to change any media parameters associated with debris removal. Debris removal must not be disabled inadvertently because it coud be harmful.


Solution

 

If you are sure that you need to change media parameters that are associated with debris removal:

  1. Use the command prm hazardous media enable to access the media parameters
  2. Change the necessary parameters
  3. Reset the device

Technical contact(s)
 

Steve Froese

Submitted by
 

Juliet Wyles

Date submitted
 

23 Sep 2002