Cannot apply mainscan and subscan shifts on Trendsetter E-model devices (MPE)


Product

 

Trendsetter 400/800 E-model (MPE) base, AL, Spectrum


Symptoms

 

GC adjustments cannot be made by changing GC parameters in firmware.


Causes

 

In the original implementation of E-model devices, the gc engc parameter is automatically set to 0 and cannot be changed. All adjustments to GC parameters are ignored in firmware.


Solution

 
  • Upgrade to the latest Controlled Release:
    • Trendsetter base: CR 1.2 or later
    • Trendsetter AL: CR 2.2 or later
    • Trendsetter Spectrum: CR 3.0 or later
  • Set the parameter gc engc to 1.

Technical contact(s)
 

Andrew So

Submitted by
 

Andrew So

Date submitted
 

14 Oct 2005


    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.