15-3466 SERVOAMP/Main Drive Amp |
||
|
|
|||
Error |
The device fails drum initialization, at times intermittently. You may receive a 6007: DRUM: Timeout on velocity settling error. Firmware may indicate that you should perform a drum cal procedure but this procedure is not available with this drum servo amp (15-3466). |
||
|
|
|||
Symptoms |
|
||
|
|
|||
Cause |
Some 15-3466 components were shipped from the manufacturer (Automotion) with an incorrect or completely ignored deadband calibration. Because this defect can manifest itself in a very intermittent manner, some of these components were likely installed in output devices that were subsequently shipped from the Annacis manufacturing plant. |
||
|
|
|||
Solution |
Check to see if the internal deadband calibration of the servo amp is incorrect as follows:
Note: Be careful not to trip the plate flyoff sensor when performing the hands-on tests. If any faults are found, replace the component (15-3466). |
||