TH1.7 "head crash" during startup of GMCE output device (EHI error #44835)


Product

 
  • Trendsetter 400/800 III (GMCE)
  • Trendsetter AL (GMCE)
  • Trendsetter CL
  • Trendsetter NEWS (GMCE)
  • TH1.7 thermal imaging head

Machines affected

 

All GMCE Trendsetter output devices with TH1.7 thermal imaging heads


Component

 

GMCE firmware


Error

 

44835: EHI: all retries failed on chnl 1


Symptoms

 

When the output device is starting up, the following error message is reported:

*** HEAD CRASH DETECTED ***
C HIM: Fatal head fault occurred: 44835
*** Unsolicited Message 44835 Fatal
[THC:all retries failed on chnl 1]


Cause

  During startup, certain signals read from the head are misinterpreted by the GMCE product firmware as indicating a crash of the TH1.7 thermal imaging head.

Solution

  You can safely ignore this error message. The head has not actually crashed, but certain signals read from the head are misinterpreted by the product firmware as indicating a crash.